Compensated 0 psi to 1psi up to 0 psi to 150 psi
FEATURES
• Precision Temperature Compensation
• Calibrated Zero & Span • Small Size • Low Noise
• Low Cost (SCX_NC) • High Accuracy (SCX_N) • High Impedance for Low Power Applications
SCX Series
TYPICAL APPLICATIONS • Medical Equipment • Barometry
• Computer Peripherals • Pneumatic Controls • HVAC
ELECTRICAL CONNECTION
The SCX series sensors provide a very cost-effective solution for pressure applications that require operation over wide temperature range. These
internally calibrated and temperature compensated sensors were specifically designed to provide an accurate and stable output over a 0 °C to 70 °C
[32 °F to 158 °F] temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air, dry gases and the like. Devices are available to measure absolute, differential and gage pressures from 1 psi (SCX01) up to 150 psi (SCX150). The Absolute (A in model
number) devices have an internal vacuum reference and an output voltage proportional to absolute pressure. The Differential (D in model number) devices allow application of pressure to either side of the pressure-sensing diaphragm and can be used for gage or differential measurements. The SCX series devices feature an integrated circuit (IC) sensor element and laser trimmed thick film ceramic housed in a compact solvent resistant case. This package provides excellent corrosion resistance and provides isolation to external packaging stresses. The package has convenient mounting holes and pressure ports for ease of use with standard plastic tubing for pressure connection.
If the application requires extended temperature range operation, beyond 0 °C to 70 °C [32 °F to 158 °F], two pins which provide an output voltage proportional to temperature are available for use with external circuitry. The 100 microsecond response time makes this series an excellent choice for computer peripherals and pneumatic control applications.
The output of the bridge is ratio metric to the supply voltage. Operation from any dc supply voltage up to 20 Vdc is acceptable.
Contact your local honeywell representative, or go to Honeywell’s website at www.honeywell.com/sensing for additional details.
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
PIN 1) TEMPERATURE OUTPUT (+) PIN 2) Vs
PIN 3) + OUTPUT PIN 4) GROUND PIN 5) - OUTPUT
PIN 6) TEMPERATURE OUTPUT (-)
Note: The polarity indicated is for pressure applied to port B. (For
absolute devices pressure is applied to port A and the output polarity is reversed)
PERSONAL INJURY DO NOT USE these products as safety or
emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNING
WARNING
Sensing and Control
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
PRESSURE RANGE SPECIFICATIONS
Model *
Operating Pressure
Proof
Pressure (2)
Full-Scale Span
Sensitivity Min. 18 mV/psi 12 mV/psi 6.0 mV/psi 6.0 mV/psi 3.0 mV/psi 3.0 mV/psi 1.0 mV/psi 1.0 mV/psi 0.6 mV/psi 0.6 mV/psi
17.82 mV 17.00 mV 59.40 mV 57.50 mV .10 mV 85.00 mV .10 mV 85.00 mV .10 mV 85.00 mV .10 mV 85.00 mV 99.00 mV 95.00 mV 99.00 mV 95.00 mV .00 mV 85.00 mV .00 mV 85.00 mV
Typ. (1)SCX Series
Max.
SCX01DN
0 psid to 1 psid 20 psid
SCX01DNC SCX05DN
0 psid to 5 psid 20 psid
SCX05DNC SCX15AN
0 psid to 15 psia 30 psia
SCX15ANC SCX15DN
0 psid to 15 psid 30 psid
SCX15DNC SCX30AN
0 psid to 30 psia 60 psia
SCX30ANC SCX30DN
0 psid to 30 psid 60 psid
SCX30DNC SCX100AN
0 psid to 100 psia 150 psia
SCX100ANC SCX100DN
0 psid to 100 psid 150 psid
SCX100DNC SCX150AN
0 psid to 150 psia 150 psia
SCX150ANC SCX150DN
0 psid to 150 psid 150 psid
SCX150DNC
* Ordering information: Order model number.
18.00 mV 18.00 mV 60.00 mV 60.00 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 100.0 mV 100.0 mV 100.0 mV 100.0 mV 90.00 mV 90.00 mV 90.00 mV 90.00 mV 18.18 mV 19.00 mV 60.60 mV 62.50 mV 90.90 mV 95.00 mV 90.90 mV 95.00 mV 90.90 mV 95.00 mV 90.90 mV 95.00 mV 101.0 mV 105.0 mV 101.0 mV 105.0 mV 91.00 mV 95.00 mV 91.00 mV 95.00 mV
GENERAL SPECIFICATIONS
Characteristic Description (Maximum Ratings) All Devices Supply Voltage (VS) 20 Vdc Common Mode Pressure 50 psig Lead Soldering Temperature 250 °C [482 °F] (2 seconds to 4 seconds)
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Compensated Operating Temperature Operating Temperature Storage Temperature Humidity Limits
Description (Maximum Ratings) All Devices
0 °C to 70 °C [32 °F to 158 °F] -40 °C to 85 °C [-40 °F to 185 °F] -55 °C to 125 °C [-67 °F to 257 °F] 0 % RH to 100 % RH
ACCURACY
Model Accuracy SCX01 through SCX150 Calibrated for span to within ±1 % (Highest accuracy) SCX01_C through SCX150_C Calibrated for span to within ±5 % (Fine adjustments of zero
and span can be provided in external circuitry)
2 Honeywell • Sensing and Control
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
SCX PERFORMANCE CHARACTERISTICS (3)
SCX Series
Characteristic Min. Typ. Max. Unit
(4)
Zero Pressure Offset -300 0.0 300 Microvolt Combined Pressure Non-Linearity and Pressure Hysteresis (5) – ±0.1 ±0.5 % FSO
(6)
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F]– ±0.2 ±0.1 % FSO
(6)
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]– ±100 ±500 Microvolt
(7)
Repeatability – ±0.2 ±0.5 % FSO
(8)
Input Resistance – 4.0 – kOhm
(9)
Output Resistance – 4.0 – kOhm
(10)
Common Mode Voltage 5.8 6.0 6.2 Vdc
(11)
Response Time – 100 – Microsec.
(12)
Long Term Stability of Offset and Span – ±0.1 – mV
SCX_C SERIES PERFORMANCE CHARACTERISTICS (3)
Characteristic Min. Typ. Max Unit
Zero Pressure Offset -1.0 0.0 ±1.0 mV
Combined Pressure Non-Linearity and Pressure Hysteresis (5) –
±1.0 % FSO – ±0.1 Models: SCX05DNC, SCX15ANC, and SCX15DNC,
Models: SCX01DNC, SCX30ANC, SCX30DNC, SCX100ANC, SCX100DNC,
±1.0 % FSO ±0.2 SCX150ANC, and SCX150DNC
(6)
Temperature Effect on Span 0 °C to 70 °C [32 °F to 158 °F] – ±0.4 ±2.0 % FSO
(6)
Temperature Effect on Offset 0 °C to 70 °C [32 °F to 158 °F]– ±0.2 ±1.0 mV
(7)
Repeatability – ±0.2 ±0.5 % FSO
(8)
Input Resistance – 4.0 – kOhm
(9)
Output Resistance – 4.0 – kOhm
(10)
Common Mode Voltage 5.7 6.0 6.3 Vdc
(11)
Response Time – 100 – Microsec.
(12)
Long Term Stability of Offset and Span – ±0.1 – mV SPECIFICATION NOTES
Note 1: Note 2: Note 3:
Note 4: Note 5: Note 6: Note 7:
Note 8: Note 9: Note 10: Note 11: Note 12:
Full-Scale Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Full-Scale Span is ratiometric to the supply voltage.
Maximum pressure above which causes permanent sensor failure. Reference Conditions: (Unless otherwise noted) T
A = 25°C, Supply VS = 12 Vdc, Common Mode Line pressure = 0 psig, Pressure applied toPort B. For absolute devices only, pressure is applied to Port A, and the output polarity is reversed. For models SCX15AN, SCX30AN, SCX100AN, and SCX150AN,
the Maximum zero pressure offset for absolute devices is 0 to ±500 Microvolt.
Pressure Hysteresis – the maximum output difference at any point within the operating pressure range for increasing and decreasing pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25 °C [77 °F] reading.
Maximum difference in output at any pressure within the operating pressure range and the temperature within 0 °C to 70 °C [32 °F to 158 °F] after:
a) 1,000 temperature cycles, 0 °C to 70 °C [32 °F to 158 °F] b) 1.5 million pressure cycles, 0 psi to Full-Scale Span. Input resistance is the resistance between pins 2 and 4. Output resistance is the resistance between pins 3 and 5.
Common Mode voltage of the output arms (Pins 3 and 5) for VS=12 Vdc.
Response time for a 0 psi to Full-Scale Span pressure step change, 10 % to 90 % rise time. Long term stability over a one-year period.
Honeywell • Sensing and Control 3
Microstructure Pressure Sensors
Compensated 0 psi to 1psi up to 0 psi to 150 psi
PHYSICAL DIMENSIONS for Reference Only (mm/in)
SCX Series
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship.
Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The
foregoing is Buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
For application assistance, current specifications, or name of the nearest Authorized Distributor, contact a nearby sales office. Or call: 1-800-537-6945 USA/Canada 1-815-235-6847 International FAX
1-815-235-65 USA INTERNET
www.honeywell.com/sensing info.sc@honeywell.com
Sensing and Control
www.honeywell.com/sensing Honeywell
11 West Spring Street Freeport, Illinois 61032
008096-1-EN IL50 GLO 1203 Printed in USA
Copyright 2003 Honeywell International Inc. All Rights Reserved
因篇幅问题不能全部显示,请点此查看更多更全内容
Copyright © 2019- oldu.cn 版权所有 浙ICP备2024123271号-1
违法及侵权请联系:TEL:199 1889 7713 E-MAIL:2724546146@qq.com
本站由北京市万商天勤律师事务所王兴未律师提供法律服务