TEST REPORT
No. : SM100303248 Date : Apr. 6,2010 Page: 1 of 4
MEEKA
No.107, CHANG YANG JIE INDUSTRIAL PARK, SUZHOU
The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name Sample Number Material and Mark Test Required Date of Receipt Test Period
Test result(s)
: Extruded Al6063 tensile test specimen : SM100303248 : Al6063 : Tensile test : Mar. 30,2010
: Mar. 30,2010 to Apr. 6,2010 :
For further details, please refer to the following page(s)
******** To be continued********
Signed for SGS-CSTC Standards
Technical Services (Shanghai) Co., Ltd
Kelly Shi Authorized signatory
TEST REPORT
No. : SM100303248 Date : Apr. 6,2010 Page: 2 of 4
Tensile test:
Test method: ASTM B 557M-06 and client’s requirement (tensile rate=10mm/min) Test item Result 1# 2# Stress-strain curve:
Tensile strength (Rm) 2(N/mm) 210 215 Yield strength (RP0.2) 2(N/mm) 159 172 Elongation after fracture(A) Gauge length=25mm, (%) 19.0 19.0 MPa300270240210180150120906030000.0020.0040.0060.0080.010.0120.0140.0160.0180.02mm/mmSample 1#
******** To be continued********
TEST REPORT
No. : SM100303248 Date : Apr. 6,2010 Page: 3 of 4
MPa300270240210180150120906030000.0020.0040.0060.0080.010.0120.0140.0160.0180.02mm/mmSample 2#
Force-displacement curve:
N800072000056004800400032002400160080000123456710mmSample 1#
******** To be continued********
TEST REPORT
No. : SM100303248 Date : Apr. 6,2010 Page: 4 of 4
N800072000056004800400032002400160080000123456710mmSample 2#
******** End of report ********